Adding Babbit Formula

Requesting addition of Babbit formula peak factor calculation to Infodrainage program, providing comprehensive analysis for efficient and accurate design and decision-making since Babbit formula peak factor calculation method used in many standard...
Mohamad Azzam about 1 month ago in InfoDrainage / Hydraulics 2 Under consideration

Auto-Profile Feature in InfoDrainage

We are asking for a Gravity Auto Profile feature in the InfoDrainage with integration with other services as sanitary, water and electrical …etc. This feature would automate the creation of longitudinal profiles for gravity-fed drainage systems (M...
Mohamad Azzam about 1 month ago in InfoDrainage / Hydraulics 3 Gathering support

Need elliptical pipe shape

need shape type
Jess Ewing 7 days ago in InfoDrainage / Hydraulics 1 In progress

Would it be possible to include longitudinal gradient (slope) to attenuation tanks please? At the moment it appears that software assumes that these structures are constructed flat whereas in real life these could be constructed with a gradient (slope) from the upstream end towards the outlet.

At the moment it appears that software assumes that these structures are constructed flat whereas in real life these could be constructed with a gradient (slope) from the upstream end towards the outlet (and this could then change the head of wate...
arek kadlec about 1 month ago in InfoDrainage / Hydraulics 1 Gathering support

Perforated Pipe as Connection Type

I would like to be able to model a perforated pipe as a connection type rather than use an infiltration trench and short branches of pipes to connect them to other stormwater controls. These infiltration trenches are not collecting inflow from sur...
Midori Patterson about 2 months ago in InfoDrainage / Hydraulics 1 Gathering support

Level Soffits in pipe network.

Although you can select Level Soffits in the Network Wizard, if you make a change in the manhole depth for example, the pipes in the network will return to invert level, which means that you will have to readjust them manually.
Konstantinos Koutroulis 3 months ago in InfoDrainage / Hydraulics 1 In progress

Simulation Health Improvements

In certain instances, the suggestions provided in "Simulation Health: The results indicate flow continuity issues, even when the shortest time step is already selected in InfoDrainage" may not resolve the problem. This could be addressed by incorp...
Guest about 1 month ago in InfoDrainage / Hydraulics 1 In progress

Lock pipe diameters only.

After simulation and there is flooding, trying to upsize the pipes, if the wizard is run again it reverts to the previous diameter, i dont want to lock (ALL) as i still want to use the wizard to lower the inverts etc, downstream.
Steven Gilchrist about 1 month ago in InfoDrainage / Hydraulics 3 Gathering support

Swale with pipe under connected by manholes

Could not model real-life scenario where the pipe was under as conveyance for lesser events and raised via vented manholes into the swale above. Need integrated solution and was unable to model both and connect via manholes.
Guest 3 months ago in InfoDrainage / Hydraulics 1 Already exists

Channel library similar to pipe library