Skip to Main Content
Autodesk
ADD A NEW IDEA

InfoWater Pro

Showing 76 of 1028

VSP Control based on Tank Head/Level

Currently you can only use Junction Pressure setpoints or Pump Flow setpoints in the VSP Control dialogue. It would be helpful to be able to use a Tank Level/Head setpoint to adjust the pump speed as well. This is possible in competitor products l...
Grant Clemens 12 months ago in InfoWater Pro / Operational Modeling 3 Under consideration

Report manager should populate without running model

Currently, the report manager is only populated once results are shown. This makes it so that the only place I can view the model data before running, is the data base manager. You should be able to have the report manager populated without runnin...
Endrit Shabani about 2 months ago in InfoWater Pro / Other 0 For Review

modeling surge check valves

I’m also wondering if you all are considering adding more options on how to model check valves.
Guest 6 months ago in InfoWater Pro / Engine 1 For Review

Customize ArcGIS Pro ribbon with command center modeling tools

While building and editing models, I want to customize easy access to tools currently burried in the Command Center (e.g. Trace Network, Join/Remove Layer tables, Clear message board, etc.). ArcGIS Pro lets you customize toolbars, but these comman...
Guest about 2 years ago in InfoWater Pro 0 Gathering support

Summarize the max velocity experienced at each pipe across all fire flow runs

While running thousands of fire flow analyses for the hydrants in my system, I want to understand the maximum velocity and other worst-case conditions experienced by each pipe across all simulations to understand capacity bottlenecks and risk.
Nathan Gerdts 11 months ago in InfoWater Pro / Automation 0 In progress

Horizontal surge tank equivalent diameter

I also am still assuming that if I want to model a horizontal tank, you must put in an equivalent diameter not the actual diameter.
Guest 6 months ago in InfoWater Pro / Productivity 0 For Review

Closed surge tank initial water level

would be nice for the surge program, is to have the initial water level automatically calculated for closed surge tanks
Guest 6 months ago in InfoWater Pro / Productivity 0 For Review

Group InfoWater Pro pumps into a pump station object that aggregates results

As a modeler I want to summarize the behavior of a pump station of multiple pumps using a polygon. This helps me summarize energy usage and total flow without needing to select arbirary upstream or downstream objects. This also helps simplify syst...
Guest over 2 years ago in InfoWater Pro / Operational Modeling 1 Gathering support

Isolation Scenario Using Dummy Valves Which Do Not Split Pipes

Can you put a valve on top of a pipe (not splitting the pipe) and then it closes the section? And then anything enclosed to these multiple valves will be isolated? This is going to be useful for modelling of isolation scenarios
Guest 3 months ago in InfoWater Pro / Operational Modeling 1 For Review

Improvements to "Edit Attributes" table

The "Edit Attributes" window (accessed by using the "Edit Selection" or "Edit Domain" buttons) is a useful table to quickly view and edit all the physical information for each facility type together. However, it has some useability issues that som...
Colin Ricks 3 months ago in InfoWater Pro / Productivity 0 For Review